Abstract:According to the features of the test of buoyancy on shallow underground structure,a model test system which directly determined the hydrostatic buoyancy on the bottom-board of the structure was developed.Main system parameters were determined based on the principle that the uplift pressure equalled the hydrostatic pressure in pure water.The buoyancy on the bottom-board of the model cellar at different embedded depths in pure water,saturated gravel,medium sand,fine sand,silt and clay were determined by the system,as well as the pore pressure.The test results show that the system’s maximum error rate of pure water buoyancy test is less than 1%.The buoyancy on the bottom-board in saturated gravel,medium sand,fine sand and silt are about 5% less than that in pure water,whereas the buoyancy in saturated clay is equal to that in pure water. During the filling of saturated silt and clay,the buoyancy is so great that it may exceed the weight of the displaced saturated soil.During the process of filling,the water heads of all piezometers are higher than the surface of the soil. Moreover,the deeper the piezometer is ebedded,the higher the piezometric head will be.At the long-term stable state,the water heads of all piezometers in clay and nonclays are exactly as high as the filling surface.