Two static tests of pinned connections between primary and secondary H beams with corrugated webs were conducted. The test results were compared with the results calculated from theoretical formulas, which validated the theoretical formulas. Design formulas for each part of the pinned connections between primary and secondary H beams with corrugated webs were proposed. The design carrying capacity of each part calculated by the design formulas were compared with the experimental results, which proved the reliability of design formulas for the pinned connections between primary and secondary H beams with corrugated webs.