高强钢平齐式端板连接节点火灾后性能数值研究
CSTR:
作者:
中图分类号:

TU391

基金项目:

国家“九七三”重点基础研究发展计划(2017YFB0304701),国家自然科学基金项目(51408150)


Numerical Study on Postfire Behavior of High Strength Steel Flush Endplate Connections
Author:
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [24]
  • |
  • 相似文献 [20]
  • | | |
  • 文章评论
    摘要:

    采用Abaqus软件对高强钢平齐式端板连接节点火灾后性能进行模拟,结果表明有限元模型能准确模拟节点的弯矩转角关系、节点失效模式和应力分布等.在此基础上,对端板采用Q460高强钢和Q345普通钢的节点进行参数分析.结果表明:在历经550 ℃火灾高温并冷却后,节点力学性能未发生明显退化;端板材料对节点初始刚度无影响,但对节点承载力影响显著;与采用较厚普通钢端板的节点相比,采用较薄高强钢端板的节点可实现相近的承载力甚至更高的转动能力.

    Abstract:

    The behavior of high strength steel flush endplate connections on postfire was simulated according to the test results using finite element software Abaqus. Comparison between the analysis results of finite element method (FEM) and all representative experimental results on momentrotation relationship, failure mode and stress distribution of flush endplate connections shows that good agreements exist. Based on above,parametric analysis on Q460 high strength steel endplate connections and Q345 mild steel endplate connections was conducted. Results show that: the degradation of mechanical behavior of the connections is not significant after cooling down from fire temperature 550 ℃; the material property of the endplate has no impact on the initial stiffness of the connections but has important impact on the bending capacity of the connections; a connection with thinner high strength steel endplate can achieve similar bending capacity and equivalent or even higher rotation capacity after fire in comparison with a connection with thicker mild steel endplate.

    参考文献
    [1]QIANG Xuhong, BIJLAARD FSK, KOLSTEIN H. Post-fire mechanical properties of high strength structural steels S460 and S690[J]. Engineering Structure, 2012, 35:1-10.
    [2]QIANG Xuhong, BIJLAARD FSK, KOLSTEIN H. Post-fire performance of very high strength steel S960[J]. Journal of Constructional Steel Research, 2013, 80(1):235-242.
    [3]COELHO AMG, BIJLAARD FSK. Experimental Behaviour of High Strength Endplate Connenctions[J]. Journal of Constructional Steel Research, 2007, 63(9):1228-1240.
    [4]COELHO AMG, BIJLAARD FSK. High strength steel in building and civil engineering structures: Design of connections[J]. Advances in Structural Engineering, 2010, 13(3):413-429.
    [5]孙飞飞,孙密,李国强,等.Q690高强钢端板连接梁柱节点抗震性能试验研究[J].建筑结构学报,2014,35(4):116-124.SUN Feifei, SUN Mi, LI Guoqiang, et al. Experimental study on seismic behavior of high-strength steel beam-to-column endplate connections[J]. Journal of Building Structures, 2014,35(4):116-124.
    [6]余红霞.火灾下钢节点牢固性的研究与展望[J].工程力学,2011,28(4):116-121.YU Hongxia. Discussions on the robustness of steel connections in fire[J]. Engineering Mechanicss,2011,28(4):116-121.
    [7]BS5950, Structural use of steelwork in building-Part 8: code of practice for fire resistant design[S], London, BSI ,1998.
    [8]SHI Gang, SHI Yong-jiu, WANG Yuan-qing, et al. Numerical simulation of steel pretensioned bolted endplate connections of different types and details[J]. Engineering Structures, 2008,30(10):2677-2686.
    [9]高义奇, 施刚, 余红霞. 拉剪组合作用下平齐端板节点火灾行为的有限元分析[J].工程力学, 2015, 32(11): 100-106.GAO Yiqi, SHI Gang, YU Hongxia. FEM analysis of flush endplate connections under the combined effect of tension and shear in fire[J]. Engineering Mechanics, 2015, 32(11): 100-106.
    [10]EN1993-1-2, Eurocode 3-Design of steel structures–Part 1–8: design of joints[S], Brussels: European committee for standardization, 2005.
    [11]EN1993-1-2, Eurocode 3-Design of steel structures–Part 1–12:Additional rules for the extension of EN 1993 up to steel grades S700 [S]. Brussels, CEN, 2005.
    [12]GB/T 11263-2010, 热轧H型钢和剖分T型钢[S],北京:中国标准出版社,2011.GB/T 11263-2010, The hot-rolled H and cut T section[S], Beijing: Standards Press of China,2011.
    [13]强旭红,石志伟,姜旭,等. 高强钢平齐式端板连接节点火灾后性能试验研究[J].湖南大学学报:自然科学版, 已录用.QIANG Xuhong, SHI Zhiwei, JIANG Xu, et al. Experimental Study on High Strength Steel Flush Endplate Connections after Fire[J]. Journal of Hunan University: Natural Sciences. (Accepted)
    [14]COELHO AMG, BIJLAARD FSK, SILVA LSD. On the deformation capacity of beam-to-column bolted connections[C]//European Convention for Constructional Steelwork -Technical Committee 10: Structural Connections (ECCS-TC10), 2002.
    [15]COELHO AMG. Characterization of the ductility of bolted endplate beam-to-column steel connections[D]. Coimbra, Portugal: University of Coimbra, 2004.
    [16]HU Ying, DAVISON JB, BURGESS IW, et al. Experimental study on flexible end plate connections in fire[C] //5th European Conference on Steel and Composite Structures, Graz,Austria, 2008: 1007–1012.
    [17]HU Ying, DAVISON JB, BURGESS IW, et al. Comparative study of the behaviour of BS4190 and BS EN ISO 4014 bolts in fire[C] //3rd International Conference on steel and Composite Structures 2007, Manchester, 2007: 587–592.
    [18]HU Ying. Robustness of flexible endplate connections under fire conditions[D]. Sheffield: Faculty of Engineering, University of Sheffield, 2009.
    [19]THEODOROU Y. Mechanical properties of grade 8.8 bolts at elevated temperatures[D]. Sheffield: University of Sheffield;,2003.
    [20]LOU Guobiao, YU Shan, WANG Rui, et al. Experimental study of mechanical properties of high-strength bolts after fire[C]// Structures in Fire :Proceedings of the 6th International Conference. East Lansing, MI:Michigan State University. 2010: 679–686.
    [21]孙飞飞,谢黎明,崔嵬,等. Q460高强钢单调与反复加载性能试验研究[J]. 建筑结构学报, 2013,34(1): 30-35.SUN Feifei, XIE Liming, CUI Wei, et al . Experimental study on material properties of Q460 high strength steel under monotonic and cyclic loading[J]. Journal of Building Structures, 2013,34(1):30-35.
    [22]WANG W, LIU T, LIU J. Experimental study on post-fire mechanical properties of high strength Q460 steel[J]. Journal of Constructional Steel Research. 2015, 114: 100-109.
    [23]靳猛,赵金城,刘明路,等. 建筑钢材高温后的力学性能分析[C]// 全国现代结构工程学术研讨会,上海,2010.JIN Meng, ZHAO Jincheng,LIU Minglu, et al. Analysis on the mechanical property of structural steel after fire[C]// The 10th National Symposium on modern structural engineering., SHANG Hai, 2010.
    [24]戴国欣,王飞,施刚,等. Q345与Q460结构钢材单调和循环加载性能比较[J]. 工业建筑. 2012,42(1): 13-17.DAI Guoxin, WANG Fei, SHI Gang, et al. Comparison of monotonic and cyclic performances of structural steel Q345 and Q460[J]. Industrial Construction. 2012, 42(1):13-17.