Effect of Low Pressure Economizer on Relatively Internal Efficiency of Steam Turbine
Author:
Affiliation:

Clc Number:

TK 223.3

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Assembling low pressure economizer is one of the important measures for energy-saving and emission reduction in power plants.An analysis is made of the 350 MW Unit installed with low pressure economizer,which consists of two linking models,series and parallel way.As exhaust gas temperature is lowered by 25 ℃,and steam state changes according to isentropic process in extraction hole,the relative internal efficiency decreases by 0.012 9% in series and 0.007 2% in parallel,and the cycle efficiency increases by 0.606 2% and 0.656 7%,respectively,and absolute internal efficiency 0.615 2% and 0.691 8%,respectively.As the extraction hole steam state is in isothermal process,the relative internal efficiency relative increases by 0.020 6% in series and 0.042 7% in parallel;cycle efficiency increases by 0.602 5% and 0.651 4% respectively,and absolute internal efficiency by 0.645 2% and 0.736 5%,respectively.

    Reference
    Related
    Cited by
Get Citation

AN Enke, MA Jianyue. Effect of Low Pressure Economizer on Relatively Internal Efficiency of Steam Turbine[J].同济大学学报(自然科学版),2010,38(10):1492~1495

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 26,2009
  • Revised:June 17,2010
  • Adopted:January 07,2010
  • Online: October 28,2010
  • Published: