Experimental Investigation on Double skin Steel concrete Composite Pylon
CSTR:
Author:
Clc Number:

TU398; U448.38

  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    Five specimens with perforated ribs and five specimens with studs were constructed to observe the experimental behaviour of double skin steel concrete composite pylon under axial load and combined constant axial load with cyclic lateral load respectively. Results of the test demonstrate the ultimate capacity and failure mode of two types of specimens with different connectors. Both perforated ribs and studs can limit the buckling wavelength of plate and to a certain extent influence the detail of failure modes. As a major influence factor, axial load level divides failure modes into two types, compression failure and tension failure. Furthermore, specimens under cyclic load show poor performance when there is high axial load or no axial load at all. At last, comparison on the bearing capacity is made between the results from experiments and calculations according to the codes, which is based on rigid plastic principle.

    Reference
    Related
    Cited by
Get Citation

ZENG Yao, WU Chong, QIN Fei. Experimental Investigation on Double skin Steel concrete Composite Pylon[J].同济大学学报(自然科学版),2012,40(10):1439~1444

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:August 29,2011
  • Revised:July 03,2012
  • Adopted:March 27,2012
  • Online: October 26,2012
Article QR Code