Seismic Evaluation and Simplified Analysis of an Existing High rise Steel Building Retrofitted with Seismic Energy Dissipated Devices
CSTR:
Author:
Affiliation:

Clc Number:

TU391;TH393.2

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Buckling restrained braces (BRBs), eccentrically braced frames and moment connections retrofitted using two side plates were incorporated into the seismic retrofitting design of a 34 story hotel tower in Kaohsiung, Taiwan. This paper discusses the analytical models for simulating the experimental responses of the BRB members, shear link beams of the eccentrically braced frames(EBFs), and the welded moment connections before and after being retrofitted by side plates. Nonlinear response history analyses (NLRHA) indicate that the peak total beam end flexural rotation demand reaches 0.01 rad, the BRB peak core strain demand is about 1.25% and the link beam total shear rotation demand reaches 0.065 rad under the maximum earthquakes, which are less than those found in the seismic building codes or laboratory tests.

    Reference
    Related
    Cited by
Get Citation

WANG Yungyu, XU Wei, WENG Yuantao, TSAI Kerchyuan. Seismic Evaluation and Simplified Analysis of an Existing High rise Steel Building Retrofitted with Seismic Energy Dissipated Devices[J].同济大学学报(自然科学版),2013,41(10):1455~1462

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 04,2012
  • Revised:July 08,2013
  • Adopted:April 07,2013
  • Online: September 29,2013
  • Published:
Article QR Code