Predicting Permissible CO Concentration Limit for Longitudinal Ventilation Tunnels under Normal Case
CSTR:
Author:
Affiliation:

Clc Number:

U453.5

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The current Chinese code Specifications for design of ventilation and lighting in highway tunnel lists the admissible CO mass concentration limits for tunnel and varies from international standards on both values and principles. Two typical types of longitudinal ventilation tunnel are longitudinal ventilation tunnel with jet fan(s) and longitudinal ventilation tunnel with jet fan(s) and vertical shaft(s). Difference form of Coburn-Forster-Kane equation (CFK equation) was introduced to calculate the CO mass concentration limits for those two types of longitudinal ventilation tunnel and a fitting equation for predicting permissible CO mass concentration limits is presented and is applicabe to both types of tunnel. The results show that the CO mass concentration limit values for long length longitudinal ventilation tunnel should be lower.

    Reference
    Related
    Cited by
Get Citation

YE WEI, ZHANG XU. Predicting Permissible CO Concentration Limit for Longitudinal Ventilation Tunnels under Normal Case[J].同济大学学报(自然科学版),2013,41(6):882~888

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 30,2012
  • Revised:February 24,2013
  • Adopted:August 23,2012
  • Online: July 08,2013
  • Published:
Article QR Code